Sprinkler Density
This calculator estimates the number of sprinklers required per acre based on different spacing. Lateral spacing is the distance between sprinkler heads in the lateral, while line spacing measures the distance between the lateral sets, or the distance between sprinkler heads in the other direction from the lateral spacing measurements. For triangular spacing, the distance between sprinkler heads is the same distance between all nearest sprinklers (equilateral triangles). The head density is the number of sprinkler heads per area. Learn more about the units used on this page.
Rectangular Spacing
Triangular Spacing
The Equations
These calculators use these formulas to determine sprinkler density
Rectangular Spacing
Where:
= Sprinkler Head Density (heads/acre)
= Line Spacing (ft)
= Lateral Spacing (ft)
Triangular Spacing
Where:
= Sprinkler Head Density (heads/acre)
= Lateral Spacing (ft)
= Line Spacing (ft)
Heading using the h2tag